Prepare the Site
WARNING: Risk of electric shock.
Disconnect power before installation or servicing.
WARNING:
Risk
of
electric
shock.
Connect
only
to
a
properly-grounded,
grounding-type
receptacle
which
is
protected
by
a
220
V
~
,
50Hz
,10A or more
Ground-Fault
Circuit-Interrupter
(GFCI)
or
Residual
Current
Device
(RCD).
Do
not
remove
the
grounding
pin
or
use
a
grounding
adapter.
WARNING: Risk of electrical shock. For hardwire installations/through-
fl
oor electrical supply:
Connect only to a properly-grounded, dedicated circuit protected by an Class A Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
NOTE:
Locating the supply stop behind the toilet will make it difficult to remove the back panel.
Install the Dock Power Cord
If the
fi
nished wall has not been installed, embed the in-wall cable conduit to route the docking station
power cord. (concealed type)
If the
fi
nished wall is installed, use the slot board cable to route the cord to the docking station location.
(out-loading type)
Install the Water Supply
IMPORTANT!
When installing the supply hose, connect it to the toilet
fi
rst, then the supply stop.
NOTE:
The supplied water supply hose is 18
″
(46 cm) in length. The supplied hose must be used for this
installation.
Install the water supply and supply stop.
Flush the water supply line into a pail or other container to remove all debris.
Silicone
Floor Flange
1-1/4" (3.2 cm) D.
Power Supply Hole
(for through-the-floor
installations only)
1-5/8"
(4.1 cm)
6" (15.2 cm)
From Finished Wall
Recommended,
11-3/4" (29.8 cm) Min
8" (20.3 cm)
Supply Stop
GFCI-
Protected
Receptacle
3" (7.6 cm) Max.
When Located
Behind Toilet
4" (10.2 cm)
Dock
Power
Cord
2" (5.1 cm)
1-1/2" (3.8 cm) D.
Water Supply Hole
(for through-the-floor
installations only)
2-5/8"
(6.7 cm)
Kohler Co.
7
1195109-T01-F
Summary of Contents for K-3900T-2
Page 1: ...Installation Guide K 3900T 2 English page 2 22 23 43 Numi Intelligent Toilet 1195109 T01 F...
Page 23: ...Kohler Co 23 1195109 T01 F...
Page 29: ...RCA 142cm 56 220V 50Hz 10A 142cm 56 Kohler Co 29 1195109 T01 F...
Page 30: ...5 16 1 2 3 4 3 2cm 1195109 T01 F 30 Kohler Co...
Page 31: ...Kohler Co 31 1195109 T01 F...
Page 32: ...T T C A B 1195109 T01 F 32 Kohler Co...
Page 33: ...A A B B C C A A A B C A B C Kohler Co 33 1195109 T01 F...
Page 34: ...2mm 2mm 13mm 1195109 T01 F 34 Kohler Co...
Page 35: ...2 Kohler Co 35 1195109 T01 F...
Page 36: ...FM Antenna Connection FM FM FM RCA FM 1195109 T01 F 36 Kohler Co...
Page 37: ...Kohler Co 37 1195109 T01 F...
Page 38: ...8 5 1195109 T01 F 38 Kohler Co...
Page 39: ...Kohler Co 39 1195109 T01 F...
Page 42: ...12 34 am 12 34 am 12 34 am 12 34 am 2 1195109 T01 F 42 Kohler Co...