3. Cut the Pipes
Measure the distance between the two marks on the inlet pipe to
determine
″
A.
″
Measure and mark
″
A
″
from the end of the side opposite the
gasket on the inlet pipe.
Cut the inlet pipe at this location.
Measure the distance between the two marks on the outlet pipe
to determine
″
B.
″
Measure and mark
″
B
″
from the end of the side opposite the
gasket on the outlet pipe.
NOTE:
Confirm the finished wall line is closer to the outlet end of
each pipe.
Cut the outlet pipe at this location.
Use a file to remove all rough areas on the cut end of each pipe.
Reinstall the pipes on the bowl.
A
B
Outlet Pipe
Inlet Pipe
B
A
1145594-2-C
6
Kohler Co.
Summary of Contents for K-6299
Page 16: ...Warranty cont This is Kohler Co s exclusive written warranty 1145594 2 C 16 Kohler Co ...
Page 37: ...Marque los tubos Lado de la pared cont Retire los tubos Kohler Co Español 5 1145594 2 C ...
Page 50: ...1145594 2 C ...
Page 51: ...1145594 2 C ...
Page 52: ...USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com 2014 Kohler Co 1145594 2 C ...