Connect Panel to the PDS (cont.)
Secure the cables to the PDS using the watertight strain relief
fittings. Thread the fitting into the box, then slide the rubber
stopper into the fitting. Tighten the cap to create a seal.
Verify all unused holes of the PDS box have the plugs installed.
Reinstall the access cover. Do not overtighten. Refer to the
″
PDS
Connection Key
″
.
Plug the PDS power cord into the outlet.
Refer to the Digital Interface User Guide to test the overhead rain
panel for proper functionality. Refer to the
″
PDS Connection Key
″
.
Troubleshooting
This troubleshooting guide is for general aid only. For service and
installation issues or concerns, call 1-800-4-KOHLER.
Troubleshooting Table
Symptoms
Probable Cause
Recommended Action
1.
Rainshower
does not light.
A.
No power to PDS.
A.
Unplug the PDS and
remove the access
cover. Plug the PDS
into the outlet. If the
LED light is not lit,
check power to
outlet.
B.
No power to
media module.
B.
Verify media module
is plugged in. Check
power to the outlet.
C.
Cable connections
to media module
are loose or
damaged.
C.
Check cables and
connections, replace
cables if necessary.
D.
PDS fuse is blown.
D.
Replace the fuse.
E.
Media module is
not assigning an
address to the PDS.
E.
Contact a Kohler
Authorized Service
Representative.
F.
PDS failure.
F.
Contact a Kohler
Authorized Service
Representative.
1078520-2-A
22