Troubleshooting (cont.)
Neckjet System
Symptoms
Probable Causes
Recommended Action
3.
Pump operates but
neckjets do not turn on.
Indicator bar on user
keypad is NOT flashing.
A.
Neckjet line is blocked.
A.
Disconnect neckjet hoses and
remove blockage.
B.
Wiring harness from neckjet to
control is loose, disconnected or
damaged.
B.
Check wiring for proper
connections. Replace wiring
harness if necessary.
C.
Butterfly valve does not work.
C.
Replace butterfly valve.
D.
Control does not work.
D.
Replace control.
4.
Water flows from neckjets,
but neckjets do not pulse.
A.
Wiring harness from neckjet
pulse canister to control is loose,
disconnected or damaged.
A.
Check wiring for proper
connections. Replace wiring
harness if necessary.
B.
Pulse canister does not work.
B.
Replace pulse canister.
C.
Control does not work.
C.
Replace control.
Remote Control
Symptoms
Probable Causes
Recommended Action
1.
Remote control does not
work.
A.
Batteries improperly installed or
dead.
A.
Replace batteries.
B.
Antenna on wiring harness is
damaged.
B.
Replace wiring harness.
C.
Remote control not programmed
correctly.
C.
See homeowners guide or service
manual.
D.
Remote control does not work.
D.
Replace remote control.
E.
Control does not work.
E.
Replace control.
Kohler Co.
15
1023274-5-C
Summary of Contents for K-856-M
Page 65: ...1023274 5 C ...
Page 66: ...1023274 5 C ...
Page 67: ...1023274 5 C ...
Page 68: ...USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com 2009 Kohler Co 1023274 5 C ...