Switch Function and Operation
WARNING : Risk of electric shock.
Make sure the power has been disconnected before performing the
following procedures.
WARNING : Risk of fire, electric shock, or injury to persons.
Ensure the grounding is connected to the
electric system. Improper insertion, no insertion or no effective grounding can result in electric shock, fire
of damage to your bath
The whirlpool controls and system have been prewired at the factory. A qualified electrician must install
Ground-Fault Circuit-Interrupter (GFCI), Earth-Leakage Circuit-Breaker (ELCB), or Residual Current Device
(RCD).
Provide a separate equipment grounding conductor for the earth lug located inside the junction box.
The grounding conductor must not be connected to any current-carrying conductor. Follow local electrical
codes. Bond in accordance with national and local codes.
Earth-Leakage Circuit-Breaker (ELCB), Ground-Fault Circuit-Interrupter (GFCI), or Residual
Current Device (RCD) Connections
Make Electrical Connection (cont.)
IMAGE
BUTTON
INSTRUCTION
Drain Controller
Turn a control handle clockwise to open
the drain.
Turn a control handle counterclockwise
to close the drain.
Jet
Turn the jet clockwise to increase the
flow.
Turn the jet counterclockwise to
decrease
the flow.
Bubble Switch Controller
To switch on: Turn a control handle
counterclockwise to open and increase
the air bubble.
To switch off: Turn a control handle
clockwise to close and decrease the air
bubble.
N
N
E
L
L
E
Control Box
Power Supply
LINE
LOAD
OFF
ON
2
P
20
A
120-240V
50/60 Hz
SENSITIVITY 15 mA
OPERATING TIME MAX. 0.1s
TEST
BUTTON
LEAKAGE
INDICATOR
INPUT
OUTPUT
Brown or Red
Green or
Green/Yellow
Blue or Black
Brown or Red -- Live (L)
Blue or Black -- Neutral (N)
Green or Green/Yellow -- Earth (E)