1276616-T01-A
C. Make Electrical Connections
WARNING: Risk of electric shock.
NOTE:
To reduce the risk of electrical shock, connect the control box to a
properly grounded, grounding-type receptacle protected by Ground-Fault Circuit-Interrupters (GFCI 's).
Electronic parameter label located on the bath. This label also identifies the electrical rating.
Your bath is equipped with a cord and plug. The blower motor has been wired at the factory. A licensed
electrician must install a dedicated GFCI-protected, 220 V, 10 A, grounded water proof outlet.
Plug the control box into this outlet.
1
1
D. Test Run the Bath
1
1
1
1
1
1
1
1
1
Check all electrical connections.
Make sure all piping connections are secure.
Temporarily remove the plastic drop cloth or other
protective sheeting from the bath.
Push the electronic drain on/off button "
" to
close the drain. Fill the bath to 350mm.
Refer to "Bath Operation" to make sure that every
function works well.
Check the piping for leaks. Repair any leaks.
Operate the bath. Check the air piping for leaks.
Stop the massage and drain water.
Return the plastic drop cloth or other protective
sheeting to the bath. Check the drain connections for
leakage.
E. Seal the Bath Rim
CAUTION: Risk of product damage.
Do not
support the weight of the bath by the rim.
For sunken type installation, construct the ceramic or
marble tiles. Seal the joints between the bath rim and
the tiled wall with silicone sealant.
Finished tiled Wall
Brick or
Concrete Wall
Bath
Silicone Filler
Paste Mortar
F. Apply Sealant to Bath with Apron
1
After the bath is fixed, apply sealant around the
connections of the bath and the wall.
Apply Silicone Sealant
Wall
Wall
6
Power On/Off
Electronic
Drain On/Off
Massage Pillow
On/Off
Massage Pump On/Off
Massage Strength Adjustment
Pipe
Cleaning
Display Panel:
Water Temperature,
Massage Strength,
Drain, Pipe Cleaning
Summary of Contents for KARESS Series
Page 11: ...1 1 1 1 QB 2585 2007 A B GFCI 11 1276616 T01 A ...
Page 13: ...A 2 mm B 80 390 2 1 1 1 1 1 13 1276616 T01 A ...
Page 14: ...B 1 1 1 1 A B C D E A 1 1 1 1 1 50 14 1276616 T01 A ...
Page 15: ...C GFCI 220 10 GFCI 1 1 D 1 1 1 1 1 1 1 1 1 350 E 15 1276616 T01 A F 1 ...
Page 16: ...H I 12mm 6mm 1800 12mm 900 600 1 A 350 16 1276616 T01 A G 1 1 1 ...