1-1/2" Bath Drain

Notes

Required Electrical Service

Measure your actual product for rough-in details.

One dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI). Outside North America,
this device may be known as a Residual Current Device (RCD).

Install this product according to the installation
instructions.

The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.

240 V, 15 A, 50/60 Hz

Blower:

Technical Information

All product dimensions are nominal.

If relocating the blower motor, do not relocate or
alter the PVC tee or coiled flexible tubing

Three-wall alcove

Installation:

Left

Drain location:

connected to the blower. Follow the blower
relocation instructions exactly. Provide access
for servicing the blower.

45" x 23" (1143 mm x 584 mm)

Basin area, bottom:

54" x 25" (1372 mm x 635 mm)

Basin area, top:

390 lbs (176.9 kg)

Weight:

61 lbs/ft² (297.8 kg/m²)

Minimum floor load:

11-5/8" (295 mm)

Water depth:

52 gal (196.8 L)

Water capacity:

Blower: 240 V, 5 A, 50/60 Hz

Electrical component

rating:

Variable

Blower speed:

2" (51 mm)

Minimum flat for door:

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to 

www.kohler.com

.

9-7-2019 13:32 - US/CA

Memoirs

®

5' BubbleMassage

 Bath

K-723-G0