24
1493936-W2-A
Symptom
Start/Stop
Light is
ON or OFF
Power
Control
Position
Possible Cause
Possible Remedy
Airboost
function fails
to operate or
will not shut
off.
ON
ANY
Air pump or control
electronics faulty.
Check connection plug
between air pump and
PCB.
Replace air pump.
Replace PCB.
Water will not
turn off.
FLASHING
ANY
Possible failure of cover
/ PCB
Replace cover / PCB.
Shower turns
off after 30
mins
OFF
ANY
Shower automatically
turns off after 30 minutes
continual use.
Turn shower back on and
use as normal.
•
There are no user serviceable parts inside the shower. Only qualified, competent
personnel should remove the front cover, mains connections are exposed when
the cover is removed.
•
Switch the shower off at the isolator switch before performing any user maintenance
or before cleaning the shower.
In the event of a malfunction of the shower, a fault finding table is provided in this
guide detailing possible causes and remedies that may be carried out by non-
qualified personnel.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, INJURY OR
PRODUCT DAMAGE:
User Maintenance
Always read the IMPORTANT SAFETY INFORMATION for your shower
Cleaning
De-scaling the Showerhead and inspecting the hose and diffuser
It is IMPORTANT to keep the Showerhead and Hose clean and free
from blockage to make sure your shower performs to its optimum. The
showerhead MUST be regularly cleaned and the hose MUST be regularly
inspected to ensure there is no internal collapse or blockage that could
reduce the flow.
Many household and commercial cleaners, including hand and surface cleaning
wipes contain abrasive and chemical substances that can damage plastics, plating
and printing and should not be used. These finishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.
Cleaning the showerhead