7
1493936-W2-A
Specifications
Electrical
Sport Max with Airboost Variant
9.0
10.8
Nominal Power at 230 V ac
8.3 kW
9.9 kW
Nominal Power at 240 V ac
9.0 kW
10.8 kW
Recommended MCB Rating
40 A
45 A
Maximum Supply Cable Size
16 mm²
Recommended RCD Rating
30 mA tripping current
Recommended Isolator Switch
45 A double-pole with 3 mm contact separation
Appliance Sealing Rating
IP X4 - Suitable for installation in Zone 1
Maximum Ambient Temperature
30°C
Minimum Ambient Temperature
2°C
Dimensions
Height
358 mm
Width
215 mm
Depth
90 mm
Plumbing
Sport Max with Airboost Variant
9.0
10.8
Minimum Dynamic Pressure
70 kPa (0.7 bar)
100 kPa
(1.0 bar)
Maximum Dynamic Pressure *
500 kPa (5 bar)
Minimum Static Pressure
20 kPa (0.2 bar)
Maximum Static Pressure *
1000 kPa (10 bar)
Maximum Inlet Temperature
30°C
Minimum Inlet Temperature
2°C
Inlet Connection
1/2" BSP Male / 15 mm Compression Fitting
Maximum Water Hardness
200 ppm CaCO
3
Outlet Connection
1/2" BSP Male
*A drop tight pressure reducing valve should be installed where dynamic or static pressure
exceeds the figure stated in the Specifications.