8
1306246-W2-D
Plumbing Supply
Supply Source
Mains pressure cold water only
Minimum Dynamic Pressure*
50 kPa (0.5 bar)
(100 kPa (1 bar) BEAB Care)
Maximum Dynamic Pressure
500 kPa (5.0 bar)
Maximum Static Pressure
1000 kPa (10 bar)
Minimum Static Pressure**
20 kPa (0.2 bar)
Maximum Inlet Temperature
30°C (20°C BEAB Care)
Minimum Inlet Temperature
2°C (5°C BEAB Care)
Inlet Connection
½" BSP male and 15 mm compression
fitting.
Outlet Connection
½" BSP male fitting
Electrical Supply
Nominal Rating at 230 V
8.0 kW
9.0 kW
Nominal Rating at 240 V
8.7 kW
9.8 kW
Supply Fuse/Circuit Breaker
8.7 kW
40 Amps
9.8 kW
45 Amps
Residual Current Device RCD
30 mA
Supply Cable
No larger than 16 mm²
Note: Refer to current IEE regulations and
BS 7671 to determine minimum cable size.
Isolation Switch
45 Amp Double pole, with 3 mm contact
separation.
Maximum Ambient Temperature
30°C
Minimum Ambient Temperature
2°C
Ingress Protection Rating / IPX4 suitable for installation within Zone 1
Dimensions (shower unit)
Height
408 mm
Width
187 mm
Depth
Flex : 112 mm , Standard : 105mm
*
Recommended dynamic pressure of 100 kPa (1.0 bar) for full flow performance.
**
Static pressure must never fall below 20 kPa (0.2 bar) when other draw offs are in use,
e.g. flushing toilet. This is the minimum pressure required to keep the flow valve closed.