17
9.
Fit the backplate over the pipes and mark the
fixing holes.
10.
Remove the backplate and drill the holes. For
solid walls use a 6mm drill for the wall plugs
supplied. For other types of wall structure
alternative fixings may be required (not
supplied).
6.
Finish the wall surface to cover the pipework.
7.
Using an appropriate pipe cutter, trim the
protruding pipework back to 30 - 35mm.
8.
Remove all burrs and sharp edges from the
pipework.
5.
Install the supply pipework. Make allowance
for the pipework to extend a minimum of 50mm
from the finished wall surface (the pipework will
be trimmed back later).
Panel / Partition Wall
Solid Wall
noggin for
overhead arm
wall mounting
Channels cut
for pipework
noggin for
pipework
50mm
minimum from
finished wall
30 - 35mm
IMPORTANT!
support pipework
from rear to aid valve
assembly