22
COMMISSIOnInG
Maximum Temperature Setting
Before using the shower, it is important to check
the maximum showering temperature is at a
safe level. The temperature has been preset
to approximately 45°C at the factory, but due
to variations in site conditions this may need
adjustment.
Note!
Make sure that the hot water temperature
is at least 60°C and that there is sufficient supply.
Mira Calibre EV
1.
Turn the shower on to full flow (lower lever turn
fully to the left).
Turn the temperature to full hot (upper lever
turn fully to the right) and allow the water
temperature to stabilise.
2.
Check the showering temperature.
_
+
Care required when disassembling
to avoid product damage.
If the temperature is too hot or too cold adjust
as follows:
3.
Turn the shower off and remove the handset
from the clamp bracket.
4.
Remove the spreader screw from the top of
the slide bar and remove the slide bar from
the wall.