19
1383572-W2-A
Check the inlet filter is in position before
connecting inlet supply.
Connect the inlet supply pipe to the inlet
connector using the compression nut and olive
(supplied).
DO NOT
use jointing pastes to make
water connection.
Support the inlet connector as shown when
tightening compression fitting.
Upon completion of the installation ensure
connections and back case are not under any
stress due to misaligned pipework or electrical
cables.
Note: DO NOT exert strain on the
terminal block. Make sure that the
electrical connections are tightly
screwed down.
Turn on the water supply and check for leaks.
Strip back sufficient outer cable insulation
to enable routing to terminal block.
Fit an earth sleeve to the earth wire (not
supplied).
Loosen the screws in the terminal block
and insert the wires.
Tighten the screws in the terminal block,
ensure the wires are secure and tight.
N
(Neutral) = Blue Wire
L
(Live) = Brown Wire
(Protective Earth) =
Green Sleeved Wire
Summary of Contents for Mira Elite SE
Page 35: ...35 1383572 W2 A Notes ...