Commissioning
Turn temperature control
to the
full cold
position.
Turn power control to
Low
.
Ensure electrical supply
is switched off and water
supply is on.
Installer:
Make sure you follow the commissioning procedure to check the function
and performance before using the shower for the first time.
Make sure that all users are familiar with the operation of the shower. Pass on
this guide to the homeowner.
Loosen the four screws and
remove the cover.
Place the shower hose
into water catchment
area. Fit the shower
hose to the outlet of the
shower (If installing the
dual product use the
short hose).
Turn shower off. Insert a suitable coin or an 8 mm hexagonal key into the cap and
turn to the left. Remove the filter from the shower unit. Push the rod up until water
flows freely. Refit the filter, turn until locked. Repeat the steps 1-3.