25
1383572-W2-A
Switch
on
the electrical supply.
Slowly rotate the bleed valve anti-clockwise until air bleeds from the pump housing.
When water flows from the bleed valve this indicates that air is removed, and the
pump is primed.
Close the bleed valve by rotating clockwise. Do not overtighten.
Fit the cover using the screws provided.
DO NOT
use electric screwdrivers to
tighten the screws.
Push START/STOP button. Wait for full
flow of water from the hose. This may
take up to 30 seconds.
Depending on the fittings installed connect the hose to the handset or
diverter. Operate the shower to ensure the product is working correctly.
Advise the homeowner how to operate the shower.
Note:
If water does not flow ensure
there are no air locks and repeat
commissioning.
Important!
Do not completely remove the bleed valve.