27
1486928-W2-A
Symptom
Possible Cause
Possible Remedy
No water or very
low flow
The hose or showerhead is
blocked.
De-scale showerhead, check hose for kinks or
damage and replace if necessary. Refer to the
User Maintenance section of the user guide.
The incoming water supply stop
valves, or the appliance isolating
valve is closed.
Open the stop/isolating valve completely.
Insufficient water supply
pressure.
Contact the local water authority
The heater tank is excessively
scaled.
Replace the heater tank assembly.
The inlet filter is blocked.
Clean the inlet filter.
The fuse is blown or the MCB
/ RCD has been tripped,
indicating a possible electrical
fault; for example, heater tank
element failure.
Switch on the power at the double pole switch.
The on / off switching assembly
is faulty.
Replace on / off switching assembly.
The start / stop switch is faulty.
Replace start / stop switch.
The solenoid coil is faulty.
Replace solenoid coil.
Water leaks from
the bottom of the
case near the
outlet and there
is no flow from
the showerhead
The pressure relief valve in the
tank has been triggered (usually
due to a blocked outlet), when
the relief valve operates a small
rubber ball is ejected.
Resolve the blocked outlet and replace the
heater tank assembly.