TROUBLE SHOOTING
PROBLEEM OPLOSSEN
Error
Cause
Remedy
Tap does not operate
“
Temporary Off
” is activated
End “
Temporary Off
” (refer to the Rada Website
for Commissioning Instructions)
Stop valve closed or filter
blocked
Open stop valve or clean filter
Battery flat
Change the battery (refer to the Rada Website
for more details)
Power failure
Check power supply
Tap flushes uncontrolled
(without use)
Reflection
Restart electronics (See electronic functions)
Setting the sensor range
Water flows permanently
Valve debris
Clean/Renew the valve
Red LED flashes when
Sensor operated.
Warning! Battery becoming flat
Change the battery
Unable to control or adjust
temperature correctly
Hot and Cold supplies fitted in
reverse
Install supplies correctly
Fout
Oorzaak
Oplossing
Kraan werkt niet
"Tijdelijk Uit" is geactiveerd
Beëindig „Tijdelijk uit“ (Raadpleeg de Rada
Website voor
Stopklep gesloten of filter
geblokkeerd
Open klep of maak filter schoon
Batterij leeg
Verwissel de batterij
Stroomstoring
Controleer stroomvoorziening
Kraan stroomt
oncontroleerbaar
(zonder te gebruiken)
Reflectie
Herstart elektronica
(Zie elektronische functies)
Instellen van het sensor bereik
Water stroomt permanent
Vuil in de klep
Schoonmaken/Klep vervangen
Rode LED knippert als
Sesnsor bediend wordt.
Waarschuwing! Batterij raakt
leeg
Verwissel de batterij
Niet mogelijk om te bedienen
of de temperatuur juist in te
stellen
Heet en Koud verkeerd
aangesloten
Installeer voorziening correct
GB
NL
Refer to Rada Website for full Maintenance and Specialised set up instructions.
Raadpleeg de website van Rada voor volledige instructies voor onderhoud en
gespecialiseerde installatie-instructies.