7
Rada PA-V8F / PA-V8FW-LL and LR Panels Only
The outlet elbow can be moved from the right hand side (RH) to the left hand side
(LH) to suit the installation of the shower fittings.
1.
Disconnect the outlet hose from the elbow.
2.
Remove the nut that holds the elbow in position and remove the elbow.
3.
Remove the nut and the washer that hold the blanking plug in position and
remove the blanking plug.
4.
Refit the elbow in the opposite side of the panel and secure in position with the
nut.
5.
Fit the blanking plug in the other hole and secure in position with the washer
and the nut.
6.
Connect the outlet hose to the elbow.
Blanking Plug
Outlet Hose
Elbow
Washer
Nut
Nut