background image

3

114014-2-

AA

 (9537)

Kohler Co., Kohler WI

4. INSTALLATION REQUIREMENTS

A. MATERIALS REQUIRED

Plumbers putty

Silicone sealant

Metal shims

Water-resistant subfloor sealant

Wall coverings, as necessary

Gypsum plaster

NOTE:  Site preparation and wall/floor finishing may
require additional materials.

B. TOOLS REQUIRED

Arc pliers or 14” pipe wrench

Rule

Level

Square

Screwdriver

7/16” ratchet or combination wrench

Conventional woodworking tools

Safety shoes

Safety glasses

Pliers

Utility knife

NOTE:  Site preparation and wall/floor finishing may
require additional tools.

 C. CLEARANCE REQUIREMENTS

Check roughing-in and room dimensions to provide
adequate space for the bath unit.

D.  NEW OR REPLACEMENT INSTALLATION

REQUIREMENTS

This bath unit can be installed in new or existing
bathrooms.

For new installations: Position plumbing according to
roughing-in dimensions located on Page 2. Cap the
supplies and check for leaks.

For replacement installations: Remove the old bath,
the old wall material, and the old finished floor material
from the area. Remove any old plumbing which does not
conform to roughing-in requirements.

5. SITE PREPARATION

A. OLD BATH REMOVAL

Disconnect the drain at the trap. Remove the old wall
material. Slip boards under old bath feet to protect
the floor 
and slide the old bath out of the recess as
illustrated.

Floor
Protection
Boards

Old Bath

Summary of Contents for REVIVAL K-873

Page 1: ... make changes in prod uct characteristics packaging or availability at any time without notice These instructions contain important care and cleaning information please leave these instructions for the consumer 2 PRODUCT REQUIREMENTS A SUMMARY OF KEY REQUIREMENTS Observe all local plumbing and building codes Install the unit level with the subfloor Provide properly dimensioned framing Make sure th...

Page 2: ...CT INFORMATION Fixture basin area top area weight Bathing well 44 x 22 52 x 29 348 lbs water depth capacity To overflow 12 1 2 58 gals Approximate measurements for comparison only C INSTALLATION NOTES Read entire installation instruction before beginning installation Fixture should be on the job site to determine dimensions Roughing In Notes Fixture dimensions are nominal and conform to toler ance...

Page 3: ...QUIREMENTS Check roughing in and room dimensions to provide adequate space for the bath unit D NEW OR REPLACEMENT INSTALLATION REQUIREMENTS This bath unit can be installed in new or existing bathrooms For new installations Position plumbing according to roughing in dimensions located on Page 2 Cap the supplies and check for leaks For replacement installations Remove the old bath the old wall mater...

Page 4: ...d wall materials Bath should be installed in a recess Possible studding arrangement is illustrated below modifications may be needed for other types of construction Recessed Installation Suggested stud construction is illustrated D PLUMBING PREPARATION Position plumbing according to roughing in dimensions Cap the water supplies and check for leaks 6 BEFORE INSTALLING UNIT A PARTIALLY INSTALL BATH ...

Page 5: ...recess area until it is shimmed properly if the feet are not accessible from the back or side Metal Shim Decorative Drain B INSTALL PLUMBING 1 When the bath is securely positioned connect the drain into the trap The drain tailpiece may have to be removed and cut to fit the trap properly Connect Here 2 Install the faucet valving and spout tee If the faucets are deck mounted the deck must be finishe...

Page 6: ...ne Sealant Drain Shroud 2 Center the drain shroud around the installed drain Be sure to align the holes in the shroud tabs with the holes in the underside of the rim Draw the outline of the drain shroud bottom edge onto the subfloor surface or a flat piece of cardboard Then measure and mark a series of closely spaced cut lines outward from the drain shroud outline These cut lines must be between 3...

Page 7: ...w Press the drain shroud tightly against the apron wall and use a 7 16 ratchet or combination wrench to tighten each screw until the drain shroud is secure NOTE Do not overtighten the screws Bath Plastic Spacer Flat Washer Hex head Screw Rim Hole Drain Shroud Tab Apply a thin bead of silicone sealant to the bottom outside edge of the shroud base Apply a second thin bead of silicone sealant close t...

Page 8: ...aucet manufacturer s instructions 12 CLEAN UP AFTER INSTALLATION When cleaning up after installation do not use abrasive cleansers as they may scratch and dull the bath surface Use warm water and a liquid detergent to clean the surface Stubborn stains paint or tar can be removed with turpentine or paint thinner Do not allow cleaners containing petroleum distillates to remain in contact with the ba...