13. Make Electrical Connections - Dedicated Circuit Models
WARNING: Risk of electrical shock.
To reduce the risk of electrical shock, connect the pump to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI). This will provide additional protection
against line-to-ground shock hazard. A 120 V, 15 A dedicated circuit is required.
WARNING: Risk of electrical shock.
Make sure the power has been disconnected before
performing the following procedures.
NOTE:
Heater is optional. Some models will not have the heater.
Locate and secure the supplied junction box a minimum of 1-1/2
″
(38 mm) above the subfloor.
The whirlpool controls and system have been prewired at the factory. A qualified electrician should
make a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains black and white wires
and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A Ground-Fault Circuit-Interrupter
(GFCI).
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor
must not
be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
Repeat the procedures for the heater. All wiring of the heater has been completed at the factory.
Pump
Electrical
Cord
Bond in accordance with applicable codes.
NOTE:
Pump model illustrated may differ from your
actual product.
Make sure air actuator tubing is
securely attached to the pump.
Neutral
Neutral
(White)
Ground
Line
(Black)
From Pump
Line
Wire Connectors
Electrician to
provide suitable
strain relief.
Junction box should be
wired as shown.
Sterling
17
1105582-2-F