D. Install Lift Rod and Stopper
·
·
·
·
·
Insert the lift rod assembly into the overflow.
Tighten the overflow hood to the overflow elbow with
the screws provided.
If necessary, assemble the lever to the overflow
hood with the Phillips screw provided.
With the drain lever in the closed position, insert the
stopper assembly into the drain.
When the drain is opened, the stopper should rise
approximately 3/8" (1cm) above the strainer.
3/8
(1
)
D.
·
·
·
·
·
Stopper
Jam Nut
Lift Toggle
Lift Rod
Spring
Turnbuckle
Locknut
E. Adjust Drain Stopper
·
·
·
·
·
If adjustment is required, remove the stopper
assembly from the drain and loosen the jam nut
below the stopper. Turn the jam nut
counterclockwise to raise the stopper or clockwise
to lower the stopper.
Tighten the nut.
If sufficient clearance cannot be obtained by
adjusting the stopper, remove the lift rod assembly
and loosen the locknut.
Rotate the turnbuckle counterclockwise to lengthen
the lift rod or clockwise to shorten the lift rod.
Tighten the locknut, reinstall the lift rod assembly
and check the clearance.
E.
·
·
·
·
·
F. Installation Checkout
·
·
·
Ensure that all connections are tight.
Open the drain.
Turn on main water supply and check for leaks.
Repair as needed.
F.
·
·
·
6
1023725-T01-A