AVV-711 Quick Book
17
5. HORIZONT AL MACHINE ALIG NMENT
Mount the Measuring transducer marked with (S) on the shafts of the stationary machine and Measuring
transducer marked (M) on the moveable machine. Connect the cables as per section 3.3, between the
Measuring transducer units and Control Display unit, or configure Bluetooth interface.
Cautions in this screen
Shortcuts in this screen
Soft foot errors should be measured and
corrected first, to eliminate unexpected
errors while aligning.
Do not forget to repeat misalignment
measure after correction complete, to
confirm results of you work
To collect new data
Tasks in this screen
To continue aligning procedure
·
Collect readings from transducers(collect
data) and start alignment
·
Continue
alignment
·
Change program parameters
·
Setup machine dimensions and
transducers distances
·
Call soft foot program
To Setup machine dimensions and
transducers distances
To Change program parameters
To call soft foot program (set machine
dimensions and transducers distances first!)
Short description of the
current program
parameters