AVV-711 Quick Book
22
Yellow clock face background means no angle currently accepted(or averaging not
complete yet) or rotating angle(to adjacent position) too small(lower than 6 degrees)
When blinks means connection to sensor not established
When blinks means no beam condition(beam does not reach target)
Light red angle sector size background means that rotation sector angle of collected
data not satisfies minimum angle sector size requirements(60 degrees minimum)
green background recommended(more than 90 degrees), but at least yellow
background(60 degrees) must be present to advance to measure misalign step.
Presence of this image means extended Y values range used(offset present)
Crossed image means auto sweep mode disabled
Means auto sweep mode activated. Auto sweep can be enabled only at the
beginning of collect data(no any data collected before)s
Aligning type sign
H – horizontal
V - vertical(flange)
C - cardan
Current reading index /
last reading index
from zero to N-1, where N =
total readings
( active)
Transducer(s) serial
number(s).
“no sensor” if data from
transducers not present
Angles from stationary and
movable side
Manual angle
Hint box
Auto sweep mode state
Rotation angle sector size,
must be more than 60
Clock face with readings
positions marked and
graphically showed angles
Beam position indicator