AVV-711 Quick Book
76
14. STRAIGHTNESS PROGRAM
SHORT EXPLANATION
Straightness program is used for straightness measurement of the object. Very long objects can be
measured using splices. Vertical objects can be measured too.
PERFORM STRAIGHTNESS ALIGNMENT
To start program select “Straightness” from main menu and press
Main screen of the program appears.
14.1 MAIN SCREEN OF THE PROGRAM (CONFIGURE POSITIONS AND CHANGE
PARAMETERS)
Cautions in this screen
Shortcuts in this screen
All required dimensions should be
properly entered(but you can edit them
later if need, measure data will not
affected)
To start new task
Tasks in this screen
To enter number of points(positions) to
measure
·
Create/modify/overview
points
·
Create/modify/overview
splices
·
Setup
parameters
·
Enter
dimensions
·
Start
measurement
·
View misalignment results(available when
all measurements taken)
·
Save
file
To set or clear all distances equal
To enter current distance
To enter splice number (optional). When
splices used you can add next splice using
this key
To change parameters(use manual data
input or data from sensor, use manual
angle input or angle from inclinometer, filter