AVV-711 Quick Book
13
If design features of the machines do not make it possible to carry out rotation of the shafts with the
measuring units mounted up to 180º, the instrument also provides smaller shaft rotation angle
measurement mode that allows possibility to enter the measuring data at positions when the shafts
rotation angle constitutes at least 60º.
3.2 SET-UP THE DEVICE
Before the beginning of the work, check the battery voltage and charge it if necessary.
Battery status is indicated by small colored image on the bottom of the screen of the device in the
main menu. Exact battery voltage can be viewed in the Setup option
Check and clean if necessary the surface of detectors and aperture of laser.
Use soft tampons, moistened with alcohol, for the cleaning. Solvents must not be used!
Check and setup if necessary, date and time of the system clock.
3.3 CONNECTING THE MEASUR ING UNITS
There are serial connector in the Control Display unit and each Measuring transducer units. Connection
to the Control Display unit is in series (Fig. 5).
Connecting the measuring units in series
Fig. 5
3.4 INPUT OF DIMENSIONS
To enable the AVV-711 to carry out accurate calculations it is necessary to input the distances between
the measuring transducer units, the coupling and the machine feet. Fig. 6 shows the dimensions input for
the horizontal plane alignment. Fig. 7 shows the dimensions input for the alignment of vertical flange
mount machine.