AVV-711 Quick Book
8
2.1.1 CE COMPLIANCE
AVV-711 alignment system conform to 2006/95/EC, EN 61010-1:2001, EN 60825-1:2007, 2004/108/EC,
EN 61326-1:2006, EN 61326-2-2:2006, EN55011:2009+A1 CE requirements
2.2. SPECIFICATION AND FEATURES
2.2.1.
Separation distance between measuring transducer units, up to 10m
2.2.2.
Display control operating temperature range, -10..+55 degree C
2.2.3.
Measurement accuracy, 1%+0.01
2.2.4.
Laser type: Visible red 635-670 nm, <1 mW
2.2.5.
Detector type: Positional-sensitive photodiodes, 10
х
10 mm
2.2.6.
Display resolution, 0.01 or 0.001 mm, (1 or 0.1 mil )
2.2.7.
Measuring resolution, 0.001mm
2.2.8.
Electronic inclinometer resolution, 0.1 degree
2.2.9.
Power supply: Rechargeable NiMH battery
2.2.10.
Gross weight, 7.5 kg
2.2.11.
Built-in application programs and options:
horizontal shaft alignment at any shaft position, from 60°, up to 360º, up to 36 readings can be
measured; auto sweep mode can be used;
vertical(flange machine) shaft alignment;
editable misalignment tolerances;
setup options;
soft foot;
thermal growth;
selection of shimming simulator to calculate for expected misalignment;
2.3. SYSTEM PACKAGE.
The System includes (Fig. 1):
AVV701 display control unit
two measuring transducer units
universal chain brackets for mounting of the
measuring units