SC-021/RC-010 Introduction Manual /Practical Version
39
Md
PE
Ax
Sp
Val
P L S R N D
O F F
0 - 9
1 2
:
1
2
Md
PE
Ax
Sp
Val
P L S R N D
O F F
0 - 9
1 2
:
1
N
Md
PE
Ax
Sp
Val
P L S C A L
D I V
N / 1
1 1
:
1
0 0 0 0 0 0 0 1
Md
PE
Ax
Sp
Val
P L S R N D
O F F
0 - 9
1 2
:
1
2
Change setting item
Into data entry
Input number
《
Setting Number of Digits for Displayed Data
》
System Setting Item 12
ⅲ)
Using the keypad, enter the desired number of digits (between 0-9) to be displayed.
ⅳ)
Press “
SET
” button again when finished.
ⅰ
)
Change setting item number to
“No.12”
at system setting status by moving dial-key up or down.
ⅱ
)
Press “
SET
” button to access
data entry screen
.
Dial-key moving up or down
Press ”SET”
Press ”SET”
Fix the setting
Enter number
of digits to be
displayed
Prior to performing the pulse number conversion explained on pages 37-38, the operator must
determine the number of digits that can be displayed on the remote control unit.
The default setting for the displayed number of digits is set to (2). Conversion results that
exceed two digits will be displayed incorrectly. The following steps explain how to increase the
displayed number of digits.