IK-12 NEXT
- 9 -
1.3.10
Electric shock prevention
The plasma system uses high voltage when arcing occurs. Please be aware of the following
points when operating.
1. Please dry your body and clothes.
2. Please do not stand or touch the wet floor when cutting the plasma.
3. Please pay sufficient attention to electric shock. Wear insulation gloves and boots as insulation
measures, especially when you must operate in the wet condition or near it.
4. Be sure to install fuses and breakers on the primary power supply side.
If an electric shock accident or a dangerous condition occurs, it is recommended to install an
emergency shutdown device so that the power supply can be cut off instantaneously.
5. Please regularly inspect cracks, cracks etc. of the cover for hoses and cables.
Exposure of wires may result in serious accident, please do not use absolutely damaged power
cord.
If you discover damage to the cables, please replace it immediately.
6. Please inspect the torch lead regularly. If you see damaged parts such as fatigue and wear,
please replace it immediately.
1.3.11
Ground of cutting surface plate
1. Make sure to connect the ground cable directly from the cutting member or securely to the
cutting surface plate.
2. Please secure the ground securely and fix it in a way not loose connection.
1.3.12
Ground
1. Make sure the ground wire of the primary power supply is securely connected to the airframe or
operation panel.
2. Make sure that the ground wire of the plasma power supply is properly connected.
3. Please tighten the earth wire firmly with bolt nut.
1.3.13
Hose
Please attach a display to distinguish the type of gas on the wall piping.
1. Do not use gas other than specified for each fluid hose.
2. Please replace the hose damaged by cracks, sparks, heat, naked fires etc.
3. Please be careful not to twist the hose.
4. To prevent damage to the hose, please laying in a safe condition on the outside of the passage
so that there is no danger of tripping.
5. Please regularly check hose, leakage, fatigue, loose fitting etc.
6. In order to prevent damage to the hose, please keep the minimum length to prevent pressure
drop and minimize the flow resistance.