IK-12 NEXT
- 27 -
Operation
Panel
Indication
Digital Display
Setting Range
Default Value
When WU-3R
not connected
400
~
1500 mm/min
400mm/min
15.748
~
59.055 inch/min
15.748 inch/min
Function
Weaving Oscillation Speed Setting
ウ
Select this mode to set the oscillation speed during weaving operation.
The digital meter displays the oscillation speed value while the carriage
is stopped and while it is traveling.
The digital meter displays the oscillation speed value while the carriage
is stopped and while it is traveling.
The oscillation speed can be changed by turning the volume switch
while the carriage is stopped and while it is traveling.
The oscillation speed can be changed by setting the multi-function
selector switch to SWING SPEED while the carriage is stopped and
while it is traveling.
Pressing the CREEP button while the carriage is stopped and the
multi-function selector switch is set to SWING SPEED starts weaving
as an independent operation. (No arc is generated in independent
operation.)
This is not used when no weaving unit is connected.
When WU-3R
connected
Operation
Panel
Indication
Digital Display
Setting Range
Default Value
When WU-3R
not connected
0
~
100.0 mm
10.0mm
0
~
3.937 inch/min
0.394 inch
Function
Weaving Oscillation Width Setting
S Select this mode to set the oscillation width during weaving operation.
Th The digital meter displays the oscillation width value while the carriage
is stopped and while it is traveling.
The oscillation width can be changed by turning the volume switch
while the carriage is stopped and while it is traveling.
The oscillation width can be changed by setting the multi-function
selector switch to SWING WIDTH while the carriage is stopped and
while it is traveling.
Pressing the CREEP button while the carriage is stopped and the
multi-function selector switch is set to SWING WIDTH starts weaving
as an independent operation. (No arc is generated in independent
operation.)
This is not used when no weaving unit is connected.
When WU-3R
connected