- 29 -
Operation
Panel
Indication
Digital Display
Setting Range
Default Value
When WU-3R
not connected
0
~
10.0 s
0s
Function
Left Torch Stop Time Setting
Select this mode to set the left torch stop time during weaving
operation. * The left torch stop time in the tack travel mode is also set
here.
The digital meter displays the left torch stop time value while the
carriage is stopped and while it is traveling.
The left torch stop time can be changed by turning the volume switch
while the carriage is stopped and while it is traveling.
The left torch stop time can be changed by setting the multi-function
selector switch to TIMER LEFT while the carriage is traveling.
Pressing the CREEP button while the carriage is stopped and the
multi-function selector switch is set to TIMER LEFT starts weaving as
an independent operation. (No arc is generated in independent
operation.)
This is not used when no weaving unit is connected.
When WU-3R
connected
Operation
Panel
Indication
Digital Display
Setting Range
Default Value
When WU-3R
not connected
―
―
Function
Origin Position Adjustment Setting
The origin position of the torch can be changed by turning the volume
switch while the carriage is stopped and while it is traveling.
Turning the volume switch clockwise moves the torch to the left.
Turning it counterclockwise moves the torch to the right.
Pressing the CREEP button while the carriage is stopped and the
multi-function selector switch is set to ORG starts weaving as an
independent operation. (No arc is generated in independent
operation.)
This is not used when no weaving unit is connected
.
When WU-3R
connected