IK-12 NEXT
- 31 -
Parameter Number Details
Parameter number
Explanation
Unintended input prevention setting
Parameter editing is enabled when the value of this parameter is
If it is any other value, input is possible only for this parameter.
Use this to prevent unintended input.
Setting range: 0000
~
9999
At shipment from factory : 0114
Not used
Arc Stabilization Time Setting
Setting range: 0
~
10.0 s
At shipment from factory: 0 s
* This setting can also be made at the WAIT TIME position of the
multi-function selector switch.
Torch Switch ON Output Time Setting (Crater Filling)
Setting range: -0.1
~
1.0 s
At shipment from factory: 0
Sets the output ON time for the arc signal.
• If the power supply setting is not self-latching (crater filling not supported),
set this parameter to 0.
• Set this value to between 0.4 and 1.0 if the power supply setting is
self-latching (crater filling supported)
・
If the value above is set and the arc is frequently interrupted, set the value to -0.1.
In this case, the signal will remain in the ON state up until the arc stop timing.
However, since the specifications of some welding power sources do not support
the setting of -0.1, set the value to 1.0 and adjust.
crater (self-latching)
''ON'
'
crater (self-latching)
''
OFF''
Welding with crater current
Welding with main current
※
Precautions on Use
Be sure to make the crater filling (self-latching) setting at the welding power source
and that at the carriage agree
Set the crater filling (self-latching) switch of the welding power source according to
the following table.
Please set in
“parameter setup mode No.0003”
the setting method of the truck
side.
Welding power source side
carriage side
crater (self-latching)
''ON'
'
-0.1 or 0.4
~
1.0
crater (self-latching)
''OFF'
'
If the settings do not agree, the welding operation
may not proceed as set. Be sure to make the crater
filling (self-latching) settings agree.
match