PNC-12 EXTREME
18
3.4 ADDITION OF PLASMA CUTTING IN STANDARD
MACHINE (WITH ARC VOLTAGE REGULATED UP)
The standard machine of this model is Oxy-Fuel cutting machine. If the customer selects plasma cutting,
plasma devices shall be added. Additional method: disassemble solenoid valve, distributor, rubber hose,
Oxy-Fuel cutting torch and Oxy-Fuel support and add plasma initial height control unit. Switch the master
control system to plasma cutting model. (Use plasma motorized Up/Down control cable to replace
solenoid valve control cable and motorized Up/Down control cable.)
3.5 ADDITION OF OXY-FUEL CUTTING FUNCTION IN
PLASMA MODEL
If the customer selects plasma cutting machine, Oxy-Fuel devices shall be added. Additional method:
install solenoid valve, distributor, rubber hose, Oxy-Fuel cutting torch and Oxy-Fuel support and remove
plasma fixture unit. Switch the master control system to plasma cutting model, and use the spanner to
tighten the connecting lock nut. Carry out pressure test through ventilation and use soap water to wipe
the connection to check if it is gas leaking. (Replace plasma motorized Up/Down control cable with
solenoid valve control line and motorized Up/Down control cable.)
3.6 GAS SUPPLY OF RELEVANT DEVICES
The gas inlet interface is the
Ф
8mm gas-type fitting. The user may decide the length of gas supply pipe
according to the distance between gas supply, device and the cutting stroke. Please use the minimum
pipeline length, thus avoiding the reduction of gas flow. The user must add an about 200-mesh gas filter
at the gas supply interface to assure clean gas source and prevent the impurities in the pipeline from
damaging the solenoid valve and blocking the cutting pipeline.
3.7 FOLLOWING OPTIONS ARE AVAILABLE UPON
CUSTOMER’S REQUEST
Addition of Second Oxy-Fuel Torch (depends on customer’s demand)
Addition of Cutting Platform (depends on customer’s demand)