background image

9999

Neonatal 

Resuscitation 

Model

LM-089

    

Instruction Manual

Thank you for purchasing the Neonatal Resuscitation Model. 
Please read this instruction manual carefully to ensure correct use of the product, 
and store it in a safe place for easy access

KOKEN CO., LTD. 

1-4-14 Koraku, Bunkyo-ku, Tokyo 112-0004 JAPAN 
URL:http://www.kokenmpc.co.jp 
E-mail:customer@kokenmpc.co.jp 

   

 

 

 

 

 

 

  

C-1-970-1-02-00

Summary of Contents for LM-089

Page 1: ... Neonatal Resuscitation Model Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo ku Tokyo 112 0004 JAPAN URL http www kokenmpc co jp E mail customer kokenmpc co jp C 1 970 1 02 00 ...

Page 2: ...s or when the product is wet as this may cause damage 4 Please avoid exposing this product to direct sunlight as much as possible when using it outdoors Caring for the model after use 1 Any oil based ink pencil chalk paint etc used will soak into the model and become impossible to remove Please do not use any of these under any circumstances 2 If the skin of the model becomes dirty please wipe it ...

Page 3: ...e with its functioning and checking that no problems occur 4 Please do not attempt mouth to mouth artificial respiration as the inside of the airway cannot be disinfected due to the structure of the model 5 Air leakage can occur during positive pressure ventilation using a bag valve mask 6 Umbilical vein catheterization can be practiced but please do not administer any actual drug solution or wate...

Page 4: ...3 Table of Contents 1 Outline and Features 2 Components and Configuration 3 Handling Airway management using equipment Pulsation of the umbilical cord 4 Specifications ...

Page 5: ...ation utilizing a bag valve mask etc 3 The airway can be managed by utilizing the tracheal tube or laryngeal mask 4 With deep seated intubation of the tracheal tube elevation of the right lung can be checked during tracheal intubation One sided lung intubation 5 A tube can be inserted for oral and nasal suction 6 Chest compression can be practiced The xiphoid process of the sternum can also be che...

Page 6: ...nts Quantity Neonatal resuscitation model main body 1 Storage bag 1 Instruction manual this document 1 mponents and Configuration Components Quantity Neonatal resuscitation model main body 1 Storage bag 1 Instruction manual this document 1 㻌 ...

Page 7: ...these Laryngeal mask Size 1 Sizes 2 and above are not compatible 㻙㻌㻢㻌㻙㻌 3 Handling Airway management using equipment Please ensure that you apply a silicone lubricant spray to the tip of the tube and within the oral cavity of the model when using the tracheal tube and laryngeal mask Inserting this equipment into the model without applying a silicone lubricant spray can cause damage The same applie...

Page 8: ...7 Product name Height Weight Neonatal resuscitation model Main body Approx 50 cm Approx 2 500 g 4 Specifications ...

Reviews: