I.7
Technical data of the SERVOSTAR™ 600 series
SERVOSTAR™
Rated data
DIM
601
603
606
610
614
620
Rated supply voltage
V~
3 x 230V
-10%
... 480V
+10%
, 50 ... 60 Hz
Rated installed load for S1 operation
kVA
1
2
4
7
10
14
Rated DC-link voltage
V=
310 - 675
Rated output current (rms value,
±
3%)
A
rms
1,5
3
6
10
14
20
Peak output current (max. ca. 5s,
±
3%) A
rms
3
6
12
20
28
40
Clock frequency of the output stage
kHz
8
Technical data for regen circuit
—
ð
Overvoltage protection treshold
V
450...900
Form factor of the output current
(at rated data and min. load inductance)
—
1.01
Bandwidth of subordinate current
controller
kHz
> 1,2
Residual voltage drop at rated current
V
5
Quiescent dissipation, output stage
disabled
W
15
Dissipation at rated current (incl. power
supply losses, without regen dissipation)
W
30
40
60
90
160
200
Internal fusing (external fusing
ð
Auxiliary supply 24V
internal 3,15 AT
Regen resistor
internal, electronic
Inputs
Setpoint 1/2, resolution 14bit/12bit
V
±
10
Common-mode voltage max.
V
±
10
Input resistance
k
Ω
20
Digital inputs
V
low 0...7 / high 12...36
mA
7
Aux. power supply, electrically isolated V
20...36
without brake
A
1
Aux. power supply, electrically isolated V
24 (-0% +15%)
with brake
A
3
Max. output current, brake
A
2
Connections
Control signals
Combicon 5,08 / 18 pole , 2,5mm²
Power signals
Power Combicon 7,62 / 4x4 + 1x6-pole, 4mm²
Resolver input
SubD 9pole (socket)
Sine-cosine encoder input
SubD 15pole (socket)
PC-interface, CAN
SubD 9pole (plug)
Encoder emulation, ROD/SSI
SubD 9pole (plug)
Mechanical
Weight
kg
2,5
3
Dimensions (HxWxT) without
connectors
mm
275x70x265
275x100x265
I.7.1
External fusing
Fusible cutouts or similar
SERVOSTAR™
601 / 603
SERVOSTAR™
606 / 610
SERVOSTAR™
614 / 620
AC supply
F
N1/2/3
6 AT
10 AT
20 AT
24V supply
F
H1/2
max. 16 AF
Regen resistor F
B1/2
4 AF
6 AF
6 AF
SERVOSTAR™ 600 Installation-manual
15
Kollmorgen
02.99
General