II.3.4
Notes on connection techniques
II.3.4.1
Tool list
Connector (Interconnectron), unit
Tool
Mat.NoS.
RES-connector 12-pole, 6SM27...107
hand crimp tool
69227
positioner
88173
assembly spanner
85511
open-jaw spanner 22 a/f
—
Power connector 8 pol., 6SM27...107
without brake
hand crimp tool
69227
positioner
88174
2 open-jaw spanners 24 a/f
—
Power connector 8 pole,
6SM27-G...107-G
hand crimp tool
69227
positioner
88173+88174
2 open-jaw spanners 24 a/f
—
SubD-connector 9-pole.
hand crimp tool
64470
II.3.4.2
Shielding connection to the front panel
- A.4.029.4/25
SERVOSTAR™ 600 Installation-manual
29
Kollmorgen
02.99 - A.4.029.4/25
Installation
Remove the outer covering of the cable
and the shielding braid from the cores
for the required length. Secure the co-
res with a cable tie.
Remove the outer covering of the cable
over a length of about 30mm, without
damaging the shielding braid.
Pull a cable tie through the slot in the
shielding rail (front panel) of the servo
amplifier.
Use the cable tie to clamp the shielding
braid of the cable firmly to the shiel-
ding rail.