IV
Commissioning
IV.1
Important notes
Only professional personnel with extensive knowledge in the fields of electrical/ drive
technology are allowed to commission the servo amplifier.
The procedure for commissioning is described as an example. Depending on the application,
a different procedure may be sensible or necessary.
In multi-axis systems, commission each servo amplifier individually.
Caution !
Check that all live connecting elements are protected from accidental contact.
Deadly voltages can be present, up to 900V.
Never disconnect any of the electrical connections to the servo amplifier while it is live.
Capacitors can still have residual charges with dangerous levels up to 300 seconds after
switching off the supply power.
Heat sinks and front panels of the amplifier can reach a temperature of up to 80°C in
operation. Check (measure) the heat sink temperatue. Wait until the heat sink has cooled
down below 40°C before touching it.
Warning !
If the servo amplifier has been stored for longer than 1 year, then the DC-link capacitors will
have to be re-formed.
To do this, disconnect all the electrical connections.
Supply the servo amplifier for about 30 min. from single-phase 230V AC to the terminals
L1 / L2. This will re-form the capacitors.
Further information on commissioning :
The adaptation of parameters and the effects on the control loop behaviour are described in
the OPERATOR SOFTWARE manual.
The commissioning of the expansion card (if present) is described in the corresponding man-
ual on the CD-ROM.
We can provide further know-how through training courses (on request).
SERVOSTAR™ 600 Installation-manual
51
Kollmorgen
02.99
Commissioning