I
General
I.1
About this manual
This manual describes the digital servo amplifiers of the SERVOSTAR™ 600 series
(standard version). You can find information about:
l
Technical data of the servo amplifier
Chapter I
l
Assembly / installation
Chapter II
l
Interfaces
Chapter III
l
Commissioning the servo amplifier
Chapter IV
l
Accessories
Chapter V
l
Transport, storage, maintenance, disposal of the servo amp.
Chapter VI
A more detailed description of the expansion cards which are currently available and the digital
connection to automation systems can be found on the accompanying CD-ROM in Acrobat-
Reader format (system requirements: WINDOWS 95 with Internet browser) in English, German
and French versions.
You can print out this documentation on any standard printer. A printed copy of the documentation
is available from us at extra cost.
This manual makes the following demands on qualified personnel :
Transport
:
only by personnel with knowledge in handling
electrostatically sensitive components.
Installation
:
only by electrically qualified personnel
Commissioning
:
onyl by personnel with extensive knowledge of
electrical technology / drive technology
I.2
Prescribed use (“Use as directed”) of the servo amplifier
The servo amplifiers are components which are built into electrical equipment or machines, and
can only be commissioned as integral components of such equipment.
The SERVOSTAR™ 600 family of servo amplifiers is to be used only on earthed three-phase
industrial mains supply networks ( TN-system, TT-system with earthed neutral point).
The servo amplifiers must not be operated on power supply networks without an earth or with an
asymmetrical earth.
If the servo amplifiers are used in residential areas, or in business or commercial premises, then
additional filter measures must be implemented by the user.
The SERVOSTAR™ 600 family of servo amplifiers is only intended to drive specific brushless
synchronous servomotors from the 6SM series, with closed-loop control of torque, speed and/or
position. The rated voltage of the motors must be at least as high as the DC-link voltage of the
servo amplifier.
Observe the reduction factor for current and power (see techn. data).
The servo amplifiers may only be operated in a closed switchgear cabinet, taking into account the
ambient conditions defined in Chapter I.7.2 .
We only guarantee the conformance of the servo amplifiers with the standards for industrial areas
(page 7), if the components (motors, cables, amplifiers etc) are delivered by Seidel Servo Drives.
SERVOSTAR™ 600 Installation-manual
9
Kollmorgen
02.99
General