AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation
8.15.6.5 Digital-Out 9, Relay contacts
Digital-Out 9 is programmable with the setup software (for more information refer to
WorkBench).
By default, the output function is defined as ready to operate output by action parameter.
If an inductive load (relay or similar) is used, a freewheeling diode must be added to the load.
Technical characteristics
Relay output, max. 30 VDC or 42 VAC, 1 A
Galvanic isolation for 24 VDC from PE
Time to close: max. 10 ms
Time to open: max. 10 ms
114
Kollmorgen | kdn.kollmorgen.com | July 2020