AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation
8.9.2 Motor single cable connection
Motors with two wire feedback systems like SFD3 or Hiperface DSL can be connected to
AKD2G by using a single Kollmorgen hybrid cable. Depending on the AKD2G version (single
or dual axis), one or two single cable motor connections are possible.
Drive type
Commutation
Axis 1
Commutation
Axis 2
Velocity/Position loop
closure
Single axis standard
X1
-
-
X21
-
-
Single axis with Option I/O
X1
-
-
X21 X22
-
Single axis with Option F3
X1
-
-
X21
-
X23
Single axis with Option DX
X1
-
-
X21 X22
X23
Dual axis standard
X1
X2
-
X21 X22
-
Dual axis with Option DX
X1
X2
-
X21 X22
X23
8.9.2.1 Motor Power, Brake and Feedback connectors X1, X2
X1 (Feedback 1) / X2 (Feedback 2)
Motor Power: 4 pin, pitch 7.62 mm
Motor Brake: 2 pin, pitch 3.81 mm
Motor Feedback: 2 pin, pitch 3.81 mm
Cable length: (
Use Kollmorgen cables
Mating connector data (
Feedback types: SFD3, HIPERFACE DSL
Rated voltage 11 V.
Rated current is 350 mA simultaneously for X1 and X2.
Pinout is identical for connectors X1 and X2.
Pin Signal
Description
1
U
Motor phase U
2
V
Motor phase V
3
W
Motor phase W
5
PE
Protective earth
B+ BR+
Brake positive line (safety notes and details (
B-
BR-
Brake negative line (safety notes and details (
F+ COM+
SFD3, HIPERFACE DSL
F-
COM-
80