AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation
8.15.6.2 Digital-Out 7 and 8
These outputs are programmable with WorkBench. By default, all outputs are not pro-
grammed (off).
Technical characteristics
The outputs can 5 V to +30 V
Galvanic isolation for 24 VDC from PE
The two channels are isolated from one another and not referred to a common potential
Output current max.100 mA
Can be wired as sinking or sourcing (see examples below)
Update rate: 250 µs
Wiring examples
112
Kollmorgen | kdn.kollmorgen.com | July 2020