AKD2G-S Installation Manual, Safety 1 | 10 Safety Manual
10.6.1.3 AXIS#.SAFE.STO.ACTIVE
Description
Indicates the Safe Torque Off (STO) state of the axis.
Value Description
1
STO active (0V)
0
STO inactive (inputs 24V)
Context
For full STO information refer to " STO (Safe Torque Off)" (
Versions
Action
Version
Notes
Implemented 02-00-00-000
General Information
Type
Read Only
Units
N/A
Range
0 or 1
Default Value
N/A
Data Type
Integer
Stored in Non Volatile Memory
No
10.6.1.4 AXIS#.SAFE.STO.REPORTFAULT
Description
This parameter indicates whether a Safe Torque Off (STO) fault will be created when the
STO input is lost while the axis is enabled.
Value Description
1
STO fault is indicated when axis is enabled and an STO occurs (default)
0
STO fault is not indicated (warning is still present)
Context
For full STO information refer to " STO (Safe Torque Off)" (
Versions
Action
Version
Notes
Implemented 02-00-00-000
General Information
Type
Read/Write
Units
N/A
Range
0 or 1
Default Value
1
Data Type
Integer
Stored in Non Volatile Memory
Yes
148