AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation
8.5.5.3 X10: 24 VDC
2 pin, pitch 5.08 mm
Spring clamps
T version
24 VDC supply voltage
Wiring example: (
Pin Signal
Description
1
+ 24 V
+24 VDC supply voltage, PELV
2
GND
Ground for 24 VDC supply voltage, PELV
8.5.5.4 X11, X12: EtherNet Fieldbus
RJ45 with built-in green/red dual-color LED
EtherCAT, EtherNet/IP*, PROFINET*
Interface Details: (
*available 2021
Pin Signal
Description
Pin
Signal
Description
1
Tx+
Tr
5
Term.
Termination
2
Tx-
Transmit -
6
Rx-
Receive -
3
Rx+
R
7
Term.
Termination
4
Term.
Termination
8
Term.
Ttermination
8.5.5.5 X13, X14: CAN bus (optional)
RJ-25
X14 IN port, X13 OUT port
Up to 1 Mbit operation
Node ID to be set by WorkBench
Interface Details: (
Pin Signal
Description
Pin Signal
Description
1
n.c.
not used
4
CAN_low
CAN bus low signal
2
Shield
Chassis
5
CAN_GND
CAN bus ground
3
CAN_high
CAN bus high signal
6
n.c.
not used
8.5.5.6 X20: Service
RJ45 with built-in green and yellow LEDs
100/10 Mbit EtherNet TCP/IP, Modbus/TCP
Supports auto-IP, DHCP and fixed IP addressing
Supports point-to-point (i.e. Auto-IP) and connection by using
network switches
Supports automatic discovery in WorkBench if in the same
sub-net.
Interface Details: (
Pin Signal
Description
Pin Signal
Description
1
Tx+
Tr
5
Term.
Termination
2
Tx-
Transmit -
6
Rx-
Receive -
3
Rx+
R
7
Term.
Termination
4
Term.
Termination
8
Term.
Termination
62
Kollmorgen | kdn.kollmorgen.com | July 2020