Technical characteristics X23, EEO1
Pulse outputs on the SubD connector X23 are 3 signals, A, B and Index, with 90° phase dif-
ference (i.e. AquadB), with a zero pulse.
5V TTL, current 60 mA
Max. number of connected slaves is determined by the loading characteristics of the
slaves, 32 slaves can be driven if the input impedance of the bias network is 10kΩ and
only one slave has a DC termination resistor.
Max signal (channel) output frequency: 3 MHz
The pulses per revolution value is settable, pulse phase shift: 90°±20°
X23
Signals EEO1
Description
6
Zero+
EEO1 output, index positive
7
Zero-
EEO1 output, index negative
11
0 V
EEO1 output, ground
12
Track A+
EEO1 output, channel A positive
13
Track A-
EEO1 output, channel A negative
14
Track B+
EEO1 output, channel B positive
15
Track B-
EEO1 output, channel B negative
Technical characteristics X41 (SFA), EEO3/EEO4
Pulse outputs on the SubD connector X41 are 3 signals, A, B and Index, with 90° phase dif-
ference (i.e. “AquadB”), with a zero pulse.
If SFA is connected to X1, the logical output is EEO3.
If SFA is connected to X2 or X5, the logical output is EEO4.
5V TTL, current 60 mA
Max. number of connected slaves is determined by the loading characteristics of the
slaves, 32 slaves can be driven if the input impedance of the bias network is 10kΩ and
only one slave has a DC termination resistor.
Max signal (channel) output frequency: 3 MHz
The pulses per revolution value is settable, pulse phase shift: 90°±20°
X41
Signals EEO3/EEO4 Description
6
Zero+
EEO3/EEO4 output, index positive
7
Zero-
EEO3/EEO4 output, index negative
11
0 V
EEO3/EEO4 output, ground
12
Track A+
EEO3/EEO4 output, channel A positive
13
Track A-
EEO3/EEO4 output, channel A negative
14
Track B+
EEO3/EEO4 output, channel B positive
15
Track B-
EEO3/EEO4 output, channel B negative
AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation