AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation
8.11.2 PROFINET
(available 2021)
AKD2G with connectivity option
P
can be connected as slaves to a PROFINET network by
using RJ-45 connectors X11 (Port 2) and X12 (Port 1). PROFINET RT or IRT protocols can
be used. The communication status is indicated by the built-in connector LEDs.
The field bus address must either be set automatically or by using the memory card.
Conn.
Name
Function
X11
Port 2
BF
ON = No Configuration, low speed, no link
OFF = No Error
Flashing 2Hz = No data exchange
X11
Port 2
Link/
Activity
ON = Connection to the EtherNet
OFF = No connection to the EtherNet
Flashing = Sends/receives EtherNet frames
X12
Port 1
SF
ON = Watchdog timeout; channel / generic /
extended diagnosis present; system error
OFF = No Error
Flashing 2Hz = DCP signal service is initiated
via the bus
X12
Port 1
Link/
Activity
ON = Connection to the EtherNet
OFF = No connection to the EtherNet
Flashing = Sends/receives EtherNet frames
Bus topology example (PROFINET)
We suggest to use Kollmorgen ENCP cables. For more possible system solutions refer to
the WorkBench Online Help.
Communication profile
For PROFINET communication profile description refer to the manual "
AKD2G PROFINET
Communication
".
96