Maintenance
l
Maintenance should be done by qualified personnel only.
l
The AKMH motor is designed to be maintenance free for normal use. Some components
however should be inspected time by time.
o
Once per year: inspect for wear including shaft grooving, seal drag, and particulate
wear. Replace the seal in case of cuts or perforations. It is recommended that seals be
replaced every 2 years under normal operating conditions.
o
Once per year: inspect cables and tubes. Replace the cable or tube in case of cuts or
perforations.
o
Once per year: inspect o-rings for wear including cuts, perforations, and any visible
damage that might compromise the sealing of the joints. In case of damages the o-
rings (flange seal and seal of rear cover) should be replaced. If the o-ring between
flange and motor housing is damaged, the motor must be replaced.
o
Once per year respectively after 2500 hours of operation: check the motor for bearing
noise. If any noises are heard, stop the operation of the motor, the bearings must be
replaced (by the manufacturer).
o
After 20000 hours of normal operation: replace all bearings after 20,000 hours of oper-
ation under rated conditions (by the manufacturer).
l
Opening the motor invalidates the warranty.
Cleaning
l
Cleaning only by qualified personnel.
l
Cleaning should take place only when the servo system is de-energized.
l
Follow IP69K standards for wash-down pressure, temperature, angle, and distance for
spray nozzle.
l
Follow chemical compatibility guidelines for washdown and cleaning.
l
Do not use wire brush or friction cleaning methods for the motor and cable surface. Use
wash down (IP69K) and wipe down practices only.
Repair / Disposal
Repair of the motor must be done by the manufacturer. Opening the motor invalidates the war-
ranty. In accordance to the WEEE-2002/96/EG-Guidelines we take old devices and acces-
sories back for professional disposal, if the transport costs are taken over by the sender.
Send the devices to:
KOLLMORGEN Europe GmbH
Pempelfurtstr. 1
D-40880 Ratingen
AKMH Installation | Table of Contents
36
Kollmorgen | March 2014
Summary of Contents for AKMH2
Page 62: ...18 4 Dimensions AKMH3 Ax flanges AKMH Installation Table of Contents 62 Kollmorgen March 2014...
Page 64: ...18 7 Dimensions AKMH4 Ax flanges AKMH Installation Table of Contents 64 Kollmorgen March 2014...
Page 66: ...18 10 Dimensions AKMH5 Ax flanges AKMH Installation Table of Contents 66 Kollmorgen March 2014...
Page 68: ...18 13 Dimensions AKMH6 Ax flanges AKMH Installation Table of Contents 68 Kollmorgen March 2014...
Page 73: ...AKMH Installation Kollmorgen March 2014 73...