12.3 Hygienic design
The Food and Drug Administration (FDA) is an agency of the United States Department of
Health and Human Services. The FDA is responsible for protecting and promoting public
health through the regulation and supervision of food safety, vaccines, biopharmaceuticals,
blood transfusions, medical devices and other products.
All exterior materials of the AKMH motor, with the exception of the cable, are FDA approved.
Any direct contact with unpacked foodstuffs is not permitted.
The "European Hygienic Engineering and Design Group" (EHEDG) is a European-based non
government organization devoted to the advancement of hygienic design and food engi-
neering. European legislation requires that handling, preparation, processing, packaging, etc.
of food is done hygienically, with hygienic machinery in hygienic premises (the food hygiene
directive, the machine directive and the food contact materials directive).
The AKMH motor is conform to the European hygienic directives.
Requirements
IP69K EHEDG (pending)
Food-Grade
Non-Food-Grade
O-Ring
necessary
necessary
Cable tube
necessary
-
Shaft seal
necessary
necessary
Application Area:
Foodstuffs and drinks industry, no direct contact with unpacked
foodstuffs. Pharmazeutical, medical laboratories.
Example:
Cutting, packing and filling without direct contact with foodstuffs.
Motor laterally or below the food.
Standards:
UL, CE, RoHs, BISSC, EHEDG (pending),
according to DIN EN ISO 14159 and DIN EN 1672-2
Surface:
Stainless steel 1.4404, roughness < 0.8 µm
Immunity:
Against tested industrial cleaning agent (
# 45), corrosion-proof
Degree of protection:
IP69K
Mounting screw*:
Stainless steel 1.4404, sealant FDA 21 CFR 175.300
O-Ring:
EPDM, FDA 21 CFR 177.2600
Shaft:
Stainless steel 1.4404
Rotary shaft seal:
Mineral filled PTFE, single lip,
mineral: FDA 21 CFR 175.300
PTFE: FDA 21 CFR 177.1500
Shaft center screw*:
Stainless steel 1.4404, sealant FDA 21 CFR 175.300
Bearing grease:
food-grade as per FDA 21 CFR 178.3570
Cable gland:
Stainless steel 1.4404, Silicone seal FDA 21 CFR 177.2600
Cable tube:
Silicone FDA 21 CFR 177.2600
Name plate:
Laser marked in housing
Size:
AKMH2 to AKMH6
* optional, included in the mounting kit
AKMH Installation | Table of Contents
44
Kollmorgen | March 2014
Summary of Contents for AKMH2
Page 62: ...18 4 Dimensions AKMH3 Ax flanges AKMH Installation Table of Contents 62 Kollmorgen March 2014...
Page 64: ...18 7 Dimensions AKMH4 Ax flanges AKMH Installation Table of Contents 64 Kollmorgen March 2014...
Page 66: ...18 10 Dimensions AKMH5 Ax flanges AKMH Installation Table of Contents 66 Kollmorgen March 2014...
Page 68: ...18 13 Dimensions AKMH6 Ax flanges AKMH Installation Table of Contents 68 Kollmorgen March 2014...
Page 73: ...AKMH Installation Kollmorgen March 2014 73...