P50330 Installation
│
Install
Kollmorgen | April 2013
14
Figure 3: Connector Diagram
2.5.2 Power
Connection
Terminals 1 and 2 connect the P5000 to the DC power supply. Please refer to section 2.3.3
for additional information on power supply considerations.
TERM 1:
POWER GND. Power supply ground terminal. This is normally wired to the DC
power supply '-'. The hard anodized aluminum mounting plate is internally connected to TERM
1.
TERM 2:
20 - 75 VDC. Power supply positive terminal. This is normally wired to the DC power
supply '+'.
It is suggested to use a black color wire for the POWER GND (terminal 1) connection and a
red color wire for the 20-75 VDC (terminal 2) connection. Using these different colors
minimizes the chance for polarity reversal when wiring the drive to the power supply. The
P5000 drive has a two second power-on reset time before the motor is energized.
Reversing the power supply polarity will blow the drive's internal
protection fuse.