15 Joint-to-Joint Plastic Rings & Rubber Bands
For applications where multiple RGM units will be assembled together in a direct joint-to-joint configuration
and sealing (IP54 or lower) is desired, Kollmorgen offers an optional seal kit for the bolted joint (RGMXX
Customer Parts Kit). This kit includes mounting screws, a plastic sealing ring (see
) and a flexible
seal band (see
).
1. Before bolting the two RGM units together, place the flexible band over the housing behind the output
plate as shown in
.
Figure 3:
Position the band at the start of the process.
2. Then place the plastic ring into the housing pilot at the output plate end as shown below in
.
Figure 4:
Placing the plastic ring into the housing pilot.
3. Confirm that the plastic ring is pushed inward until it is flush with the housing as shown in
,
so it does not obstruct access to the threaded holes on the OD of the mounting plate.
RGM User Manual | 15 Joint-to-Joint Plastic Rings & Rubber Bands