background image

Operational Manual

EDU2AE/FR  2.00

Torque range: 0.2-50 Nm

U

IDENTIFICATION DATA OF THE MANUFACTURER

KOLVER S.r.l.

VIA M. CORNER, 19/21

36016 THIENE (VI) ITALIA

U

IDENTIFICATION DATA OF THE PRODUCT

MODEL:

EDU 2AE/FR

CODE:

032000/FR

TECHNICAL DATA OF THE PRODUCT

FUSE: 3.15 A

DIMENSIONS: 195 x 170 x h110 mm  WEIGHT: 2,4 Kg

DECLARATION OF CONFORMITY

KOLVER S.r.l.

declares that the new tool here described

: control unit model EDU 2AE/FR is in conformity

with  the  following  standards  and  other  normative  documents:  2006/42/CE,  LVD  2014/35/UE,  EMCD
2014/30/UE, EN 62841, EN 60204-1, EN 61000-6-2, EN 61000-6-4.
It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863).

Name:

Giovanni Colasante

Position:

General Manager
Person authorized to compile the technical file in Kolver.

Thiene, January 1

st

2020

Giovanni Colasante

Summary of Contents for 032000/FR

Page 1: ...DECLARATION OF CONFORMITY KOLVER S r l declares that the new tool here described control unit model EDU 2AE FR is in conformity with the following standards and other normative documents 2006 42 CE LV...

Page 2: ...3 parameters voltage frequency and current according to the selected options The AC 90 260V 50 60Hz power supply is converted into 40VDC required by the PLUTO series screwdrivers through a switching b...

Page 3: ...nter the menu press ESC for 2 seconds Select the line by pressing or then press OK the symbol will turn into Press or to select the required value and then confirm through OK or ESC if you don t want...

Page 4: ...using this option with self tapping screws ATTENTION Reaching the torque while the ramp is still on will activate the screw OK signal anyway this option is useful if you need to tighten screws that a...

Page 5: ...the function select OFF by pressing as many times as needed ATTENTION During the reverse it is necessary to keep the lever or the start signal pressed as long as it won t stop Correct screw will be d...

Page 6: ...Press ESC when ON press ESC to reset the control unit When OFF the control unit resets automatically after an error signal INTERPRETATION OF ACOUSTIC SIGNALS The control unit emits sounds which help y...

Page 7: ...Vers 280519 7 I O CONNECTIONS CN1 CONNECTOR 10 pin On the back panel in all the EDU 2AE units there is a 10 pin I O connector...

Page 8: ...es when the motor turns during screwing Signal is 24V 5 SCREW OK Correct screw signal The green led on the front panel will switch on Signal is 24V INPUT 6 NOT USED Not used 7 STOP MOTOR Remote motor...

Page 9: ...utput signals are protected from an appropriate circuit Overload of the available signals 450 mA or short circuit will result in the stop of the unit To re activate signals it is necessary to switch o...

Page 10: ...y 12 Protection 12A is displayed on the status bar it happens when current on mosfets of bridge H is 12 A for at least 1 sec Reduce cycle rate and check settings Avoid motor stalling Unscrewing too he...

Page 11: ...correct or incorrect OK the torque has been correctly reached all the selected parameters are satisfied and the control unit will give out a beep sound of 0 5 sec NOK the torque has been reached durin...

Page 12: ...Vers 280519 12 EXPLODED VIEW EDU2AE FR...

Page 13: ...ront panel EDU2AE 1 818002 12 Connector M12 5 pin nut ferrite 1 201666 R1 13 Display EDU2AE 1 852522 14 Zn white nut M3 7 800056 15 Washer M3 5 800041 16 Plastic support 4 800016 B 17 Bottom panel EDU...

Page 14: ...ree of charge such items 3 This guarantee does not cover repair or replacement required as a consequence of products which have been abused misused or modified or which have been repaired using not or...