Vers. 100822 Page 32
SERIAL PRINT:
Every control unit is supplied with a 9 pin serial female connector (connection pin: PIN 2 = TX, PIN 3 = RX,
PIN 5 = GND) and a mini USB connector. You can print the results of each screwing on a printer (for example
Kolver model PRNTR1) and/or on PC (for example through Hyper Terminal or Realterm or any data
transmission program or EDU EXPAND). You can also save those results on a USB device. The transmission
characteristics (only serial and USB) are the following: 9600 (bits per second), 8 (data bits), n (no parity), 1
(bits stop 1).
The print string is the following:
SCREW
SEQUENCE
STAGE
TORQUE
ANGLE
DATE
HOUR
NOTICE
BC: Barcode =
it begins with “BC:” and it’s followed by the code of the scanned product.
Result
= screwing result: correct or incorrect.
OK = the torque has been correctly reached, all the selected parameters are satisfied and the control
unit will give out a beep sound of 0.5 sec.
NOK = the torque has been reached during ramp time or Fast Speed (see error table). In this
case, the unit will give out 2 beep sounds and the red led will light up.
PR: Program number =
it indicates the running program.
Model =
Model of screwdriver you’re using.
T%: Torque%
= percentage of the set torque level.
S: Speed
= preset speed value.
ST: Screwing time
= it indicates the time of the screwing.
Screw: Number of screws
= number of tightened screws/total number of screws.
Seq: Sequence stage =
it indicates the stage of the sequence.
T: Torque
= torque value.
A: Angle =
angle value.
Notice
= in case of program end, it prints “Program End”, in case of sequence end, it prints “Seq. end” or it
indicates the type of error (see paragraph: trouble shooting).
EDU EXPAND
BARCODE
RESULT
PROGRAM
NUMBER
MODEL
TORQUE%
SCREWING
TIME
SPEED